| type FCD |
Galvanised steel core, leadfree PVC cover. |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -20°C / +80°C |
| IP rating |
: IP 54 |
| Compression resistance |
: 3 = 750 N |
| Impact resistance |
: 3 = 2 J |
| Tensile strength |
: 3 = 500 N |
 |
|
 |
 |
| Properties |
| FCD: Light and flexible |
 |
| Applications |
| Type FCD is, among others, being used in the building-industry, connection of control panels and protection against rodents. FCD is applied for quick and easy mounting and a light to medium mechanical protection. |
 |
 |
 |
|
|
 |
 |
 |
| type FCD-EF |
Galvanised steel core, leadfree PVC cover. |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -20°C / +80°C |
| IP rating |
: IP 68 |
| Compression resistance |
: 3 = 750 N |
| Impact resistance |
: 3 = 2 J |
| Tensile strength |
: 3 = 500 N |
 |
|
 |
 |
| Properties |
| FCD-EF: IP 68-liquidtight and extra flexible. |
 |
| Applications |
| Type FCD-EF is mainly used in the apparatus- and machine- building industry where tight bending diameters are involved and light to medium mechanical protection is needed. In combination with the IP 68 fittings a complete liquidtightness can be achieved. |
 |
 |
 |
|
|
 |
 |
 |
| type FCD-PU |
Galvanised steel core, halogen free thermoplastic cover (polyurethane). |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -45°C / +105°C |
| IP rating |
: IP 68 |
| Compression resistance |
: 3 = 750 N |
| Impact resistance |
: 3 = 2 J |
| Tensile strength |
: 3 = 500 N |
 |
|
 |
 |
| Properties |
| FCD-PU: IP68-liquidtight , extra flexible, halogen free and superior chemical resistant. |
 |
| Applications |
| Type FCD-PU is particularily used for applications where light to medium mechanical protection is needed in combination with frequent movements at higher and lower temperatures, like in the subway-, train- and busbuilding industry. The IP 68 fittings provide the excellent liquidtightness which is needed for "rolling stock". Type FCD-PU is also used in situations where a better chemical resistance is required. |
 |
 |
 |
|
|
 |
 |
 |
| Sealtite EF-M |
Galvanised steel core, leadfree PVC cover. |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -20°C / +60°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 3 = 750 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
 |
 |
| Properties |
| Sealtite EF-M: Medium mechanical strength. |
 |
| Applications |
| Type Sealtite EF-M is, among others, being used in machine-building, woodcutting-machinery, connection of control panels and packaging-machinery. Sealtite EF-M is applied for semi-static installation and a reasonable mechanical protection. |
 |
 |
 |
|
|
 |
 |
 |
| Sealtite EF |
Galvanised steel core, leadfree PVC cover. |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -25°C / +70°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 4 = 1250 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
 |
 |
| Properties |
| Sealtite EF: Robust and universal. |
 |
| Applications |
| Sealtite EF can be used in many areas. The EF is, among others, being used in the apparatus- and machine-building, panel-building, packaging-machines, machines for the paper-recycling industry, machines for the pharmacy-industry and other internal transport-systems. |
 |
 |
 |
|
|
 |
 |
 |
| Sealtite OR |
Galvanised steel core, leadfree PVC cover. |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -15°C / +100°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 4 = 1250 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
 |
 |
| Properties |
| Sealtite OR: Robust, extra oil and grease resistant. |
 |
| Applications |
| Type Sealtite OR is specially developed for areas where conduit systems are being exposed to oils and greases. As a result of the high resistance against these substances the flexibility of the conduit is being safeguarded. With other (non-resistant) covers these substances can lead to stiffening or even rupture of the cover. This conduit can be used in many areas, such as the machine-building industry, diesel-engines, generator-sets, metal, paper, chemical and petrochemical industry. |
 |
 |
 |
|
|
 |
 |
 |
| Sealtite HC |
Galvanised steel core, PVC cover. |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -45°C / +105°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 4 = 1250 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
 |
 |
| Properties |
| Sealtite HC: Robust, wide temperature range. |
 |
| Applications |
| Type Sealtite HC is prefered in areas where conduit systems are being exposed to strong variations of temperatures and is, amongst others, being applied in train-warning-systems, transformers, woodcutting-machines, saw-machines, security systems in energy plants, chemical, ceramic and building industry. |
 |
 |
 |
|
|
 |
 |
 |
| Sealtite HCX |
Galvanised steel core, thermoplastic cover (TPE). |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -55°C / +145°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 4 = 1250 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
 |
 |
| Properties |
| HCX: Rubust, extreme temperature range. |
 |
| Applications |
| Type HCX can be used at extreme high and extreme low temperatures. The HCX even keeps its full flexibility at low temperatures. Type HCX is often used in the train-building, for rolling stock and installations, off-shore, steelworks, foundries, apparatus- and machine-building, especially for outside installations. |
 |
 |
 |
|
|
 |
 |
 |
| SHIELDTITE |
Bronze core, leadfree PVC cover. |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -45°C / +105°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 4 = 1250 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
 |
 |
| Properties |
| SHIELDTITE: Robust and EMI / EMP shielding. |
 |
| Applications |
| The SHIELDTITE conduit has been developed according to MIL-STD 1310D (military standard USA) and has a fully inter-locked construction with a bronze core. This results in excellent shielding against electromagnetic fields, which is one of the most occurring disturbing factors of electronic equipment. To exclude any disturbances in your data-transport or apparatuses, SHIELDTITE will be the best solution. SHIELDTITE is used in machines and apparatuses, which need to be shielded effectively from EMI and EMP fields, like for example in the military sector, marine and air-traffic control. |
 |
 |
 |
|
|
 |
 |
 |
| Sealtite HFX |
Galvanised steel core, halogen free thermoplastic cover (Polyurethane). |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -45°C / +105°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 4 = 1250 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
 |
 |
| Properties |
| HFX: Robust, halogen free, very flexible, good flame properties (tested acc. NF F 16 101) and superior chemical resistance. |
 |
| Applications |
| Type HFX is very suitable for installations, which are subject to frequent movements as HFX keeps its excellent flexibility even at low temperatures. Type HFX is often being applied in the subway-, train- and bus-building industry, in closed areas, airports, tunnels and (subway) stations, but also in the chemical and petrochemical industry. |
 |
 |
 |
|
|
 |
 |
 |
| Sealtite ZHLS |
Galvanised steel core, halogen free thermoplastic cover (Polyolefin). |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -25°C / +80°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 4 = 1250 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
 |
 |
| Properties |
| ZHLS: Robust, halogen free, low smoke and excellent flame properties (tested acc. NF F 16 101). |
 |
| Applications |
| A halogen free, ‘low smoke’ conduit for use in public areas. The features of the ZHLS cover are necessary in the field of environment and safety, as the European guidelines state that materials used in certain areas must meet special requirements regarding toxic gas emission and smoke density in case of fire. Type ZHLS is optimal for use in the subway-, train- and bus-building industry, in closed areas, airports, tunnels, (subway) stations and other infra-structure projects, but also in hospitals, elevators, escalators and other public areas |
 |
 |
 |
|
|
 |
 |
 |
| Sealtite HTDL |
Galvanised steel core, with integral copper grounding wire, PVC cover. |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -45°C / +105°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 4 = 1250 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
 |
 |
| Properties |
| HTDL: Robust, UL & CSA approved and wide temperature range. |
 |
| Applications |
| Type HTDL is the most used Anaconda Sealtite® conduit with integral grounding copper wire (till 1.1/4"). The HTDL is UL & CSA approved and has a wide temperature range. Because of the integrated copper grounding wire the HTDL also offers a fine EMI/EMP shielding, which makes it useable for applications where a high degree of electrical continuity is required. Type HTDL is perfectly suited for machines and installations that will be exported to countries outside Europe. You will find type HTDL in transformers, paper-recycling machinery, internal transport, trains, air-traffic-control, UMTS systems, off-shore and apparatus-building industry. |
 |
 |
 |
|
|
 |
 |
 |
| Sealtite ZHUA |
Galvanised steel core, with integral copper grounding wire, halogen free thermoplastic cover (Polyurethane). |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -45°C / +80°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 4 = 1250 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
 |
 |
| Properties |
| ZHUA: Robust, UL approved, halogen free, very flexible and good flame properties (UL94-V0). |
 |
| Applications |
| Type ZHUA is the ultimate Sealtite conduit with integral grounding copper wire (till 1.1/4"). The ZHUA is UL approved and has a wide temperature range. Because of the integrated copper grounding wire the ZHUA also offers a fine EMI/EMP shielding, which makes it useable for applications where a high degree of electrical continuity is required. Another unique feature of the ZHUA is, that it is extremely flexible at both high as low temperatures. The ZHUA is often being applied in the subway-, train- and bus-building industry, in closed areas, airports, tunnels and (subway) stations. Especially for export projects outside Europe. |
 |
 |
 |
|
|
 |
 |
 |
| Galvanised steel Anamet fittings |
Galvanised steel fitting consisting of 3 parts (counter nut, ferrule and body). |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -55°C / +165°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 5 = 4000 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
|
 |
| Properties |
| Anamet fittings: UL & CSA approved and wide temperature range. |
 |
| Applications |
| The galvanised steel Anamet fittings can be used with all types of Anaconda Sealtite (except CNP) and are particularly used where a wider temperature range is required (for instance with type HCX). Because of the UL & CSA approvals the fittings are also suitable for export projects outside Europe. |
 |
 |
 |
|
|
 |
 |
 |
| Nickel-plated brass Anaconda fittings |
Nickel-plated brass fitting, consisting of 4 parts (counternut, PA clampring, ferrule and body). |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -45°C / +105°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 5 = 4000 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
|
 |
| Properties |
| Anaconda fittings: Universal, UL & CSA approved and extra corrosion resistant. |
 |
| Applications |
| The nickel-plated brass Anaconda fittings can be used with all types of Anaconda Sealtite (except CNP). This Anaconda fitting is the most used universal fitting and offers great corrosion protection in combination with a nice appearance. Because of the UL & CSA approvals the fittings are also suitable for export projects outside Europe. |
 |
 |
 |
|
|
 |
 |
 |
| ATEX approved fittings |
Nickel-plated brass fitting, consisting of 7 parts (counternut, PA clampring, ferrule, intermediate part, pressure ring, sealing rubber and body) Also available in stainless steel (AISI 316). |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -40°C / +100°C |
| IP rating |
: IP 66 / 68 |
| Compression resistance |
: 5 = 4000 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
|
 |
| Properties |
| ATEX approved fittings: ATEX certified, Ex I M2 / II 2 GD as well as Ex d I / Ex e I / Ex d IIC / Ex e II / Ex tD A21 and extra corrossion resistant. |
 |
| Applications |
| ATEX approved fittings are required for all European applications in potentially explosive atmospheres. They are frequently used in the food industry, off-shore, chemical and petrochemical industry. Typical applications are connections on big motors, transformers, control equipment and terminal boxes. The special ATEX cable-hose-fitting fits directly on every type of Anaconda Sealtite (except CNP) and by using the right connectionset also on non-covered types like SL, SLI, SLB, UIG and UI. There is also a standard ATEX cable-fitting to be used in combination with regular male NPT fittings or NPT threaded rigid pipe. |
 |
 |
 |
|
|
 |
 |
 |
| Sealtite EFL |
Aluminum core, leadfree PVC cover. |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -20°C / +60°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 3 = 750 N |
| Impact resistance |
: 3 = 2 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
 |
 |
| Properties |
| EFL: Lightweight and extra corrosion resistant. |
 |
| Applications |
| Type EFL is used in the general machine industry and train-building industry but also in military/naval applications where weight is important and non-magnetic materials are needed. |
 |
 |
 |
|
|
 |
 |
 |
| Sealtite HCI |
Stainless steel (AISI 304) core, leadfree PVC cover. |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -45°C / +105°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 4 = 1250 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
 |
 |
| Properties |
| HCI: Robust, wide temperature range and extra corrosion resistant. |
 |
| Applications |
| If we look at wider temperature ranges the Sealtite type HCI is a good solution. In addition the type HCI has a stainless steel square-locked inner hose which guarantees a high corrosion resistance. Type HCI can be used in areas where strong temperature changes occur and corrosion resistance is needed and is among others, being applied in the food industry, transformers, off-shore, foundries, chemical and ceramics industry. |
 |
 |
 |
|
|
 |
 |
 |
| Sealtite HFI |
Stainless steel (AISI 304) core, halogen free thermoplastic cover (Polyurethane). |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -45°C / +105°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 4 = 1250 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
 |
 |
| Properties |
| HFI: Robust, halogen free, very flexible, good flame properties (tested acc. NF F 16 101), superior chemical resistant and extra corrosion resistant. |
 |
| Applications |
| A halogen free conduit for use in public areas. The features of the HFX cover are necessary in the field of environment and safety, as the European guidelines state that certain areas need to be free of halogens. The HFI has two unique features, that it is extremely flexible at both high as well as at low temperatures and extra corrosion resistant because of the stainless steel inner hose. This makes the HFI very suitable for installations in the chemical and food-processing industry, but also in the off-shore, tunnels, train- and bus-building industry , in closed areas, airports and (subway) stations. Type HFI is the solution for the combination of chemical resistance, absence of halogens and high corrosion resistance. |
 |
 |
 |
|
|
 |
 |
 |
| Sealtite HCXI |
Stainless steel (AISI 304) core, lead free thermoplastic cover (TPE). |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -55°C / +145°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 4 = 1250 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
 |
 |
| Properties |
| HCXI: Robust, extreme temperature range and extra corossion resistant. |
 |
| Applications |
| Type HCXI can be used at extreme high and extreme low temperatures. The HCXI even keeps its full flexibility even at low temperatures and the stainless steel inner hose makes the HCXI extra corrosion resistant. Type HCXI is often used in the train-building (for rolling stock and installations) off-shore, steelworks, foundries, apparatus- and machine-building, especially for outside installations. Type HCXI is the solution for extreme temperatures and high corrosion resistance. |
 |
 |
 |
|
|
 |
 |
 |
| Stainless steel Anaconda fittings |
Stainless steel (AISI 303 / 316) fitting, consisting of 4 parts (counternut, PA clampring, ferrule and body). |
|
 |
 |
 |
| EN 50086 classification: |
|
 |
 |
| Temperature range |
: -45°C / +105°C |
| IP rating |
: IP 67 |
| Compression resistance |
: 5 = 4000 N |
| Impact resistance |
: 4 = 6 J |
| Tensile strength |
: 4 = 1000 N |
 |
|
|
 |
| Properties |
| Stainless steel Anaconda fittings: Universal, UL & CSA approved and superior corrosion resistant. |
 |
| Applications |
| The stainless steel Anaconda fittings can be used with all types of Anaconda Sealtite (except CNP). These fittings are available in AISI 303 and AISI 316 and offer superiour corossion resistance. These stainless steel Anaconda fittings are mostly used in the off-shore, chemical and food industry. Because of the UL & CSA approvals the fittings are also suitable for export projects outside Europe. |
 |
 |
 |
|
|
 |
 |
 |
|
|
 |
|
|